Standard oxygen transfer rate to actual, at the entered alpha
factor, standard oxygen transfer efficiency, diffuser submergence and
diffuser fouling factor — the four inputs the aerobic block requires
and applies. Dissolved-oxygen saturation follows the
Benson–Krause relation, which reproduces the reference appendix's
table to ±0.001 mg/L across 0–40 °C — it did not, once, and that is
on the verification page.
Two site conditions carry into both. Site elevation fixes the
barometric pressure from the ISO 2533 standard atmosphere, and the
pressure factor Ω, which is P_b/P_s, multiplies the driving force
in Eq. (5-70): at 2,240 m the pressure is 77.15 kPa against 101.325
at sea level, Ω is 0.7615, and the oxygen transfer duty rises by a
factor of 1.423 — about 79% more aeration energy. Ambient air
temperature sets the density of the air the blowers draw, from
Appendix B-3. It is used at the blower inlet and the model adds no
blower-house rise, so a designer who wants that allowance enters it
in the field.
The blower computes shaft power, pressure ratio, air mass flow and
specific power at those conditions, and reports air flow twice,
normal and actual at the inlet: a 500 Nm³/h duty is 679 actual
m³/h at 2,240 m and 30 °C. It compares its duty against the process air the
reactors downstream actually call for. If those two disagree, a check
says so. That block ignored its own inputs until the verification
found it.